¡ö Specification, material and style of sterilization
specification |
material |
Style of sterilization |
|
length |
width |
|
10~100 cm |
5~50cm |
Standard component |
UK 60 g/©O Medical self-adhesive dialyzing paper + PE/PET Medical white compound film |
Gamma ETO |
|
Optional component |
UK 60 g/©O Medical self-adhesive dialyzing paper + PE/PET Medical white compound film |
|
UK 70 g/©O Medical self-adhesive dialyzing paper with glue + PE/PET Medical white compound film |
|
French 83 g/©O or French¡¢America 60g/©O Medical self-adhesive dialyzing paper + PE/PET Medical white compound film |
|
Domestic 60 g/©OMedical dialytic coated paper + PE/PET Medical white compound film £» |
|
UK¡¢French or America 60g/©O Medical self-adhesive dialyzing paper + CPP/PET Medical high-temperature blue compound film |
ETO Steam |
¡ö Product package
200 pcs/bunch, or PE bag, Exterior A = A corrugated paper, interior 0.44MM PE bag. The volume of boxes can be adjusted according to customer¡¯s requirement. ¡£
¡ö Using area
Applicable to various medical institutions, such as using for sterilized packaging of hospitals combination of medical surgical kits, care packages and other sterilization equipment; , As well as medical equipment manufacturers, such as using for sterilized packaging of medical catheters, syringes, surgical kitsand other combinations.
¡ö Using method
¢ÅChoose the right sterilized bags according to the size of items. Put the clean and dry items into the sterilized Paper-Poly Bag, the items should not exceed 3 / 4~~1/2 space of the sterilized bag to guarantee a sufficient closure, otherwise the burst possibility of sterilized bags will be increased.
¢ÆSharp instruments should be placed contrary from the stripping direction, to ensure safety.
¢ÇClose the bag with sealing machine and write down the sterilized time, content and use information; Keep 1-2.5cm distance from the stripping place while sealing the bag.
¢ÈThermal cover should combine with the plastic surface of sterilized bag; Thermal sealing temperature is 180-220 ¡ã C; Pressure 0.15kg/cm2, the delay time is 4-6S. (Based on the difference between performance of equipment, and security of sterilized packaging products, the parameters should be officially confirmed before using)
¢ÉPut the closed sterilized bags in the related sterilized equipments, and sterilize according to relevant international standard requirements.
¢ÊShould confirm if the discoloration of chemical indicator is consistent with the discoloration of the sterilized bags after sterilize.
¢ËThe products can not be used immediately after sterilize, they should be stored in cool, dry, ventilation and non-corrosive gas environments.
¢ÌThe sterilized bag should be torn by the unsealed direction. Should be holding two torn edge while dissecting, and open it with uniform balance.
¢ÍSteam sterilization should be used in six months; ETO sterilization should be used in 24 months.
¢ÎCheck the sterilized bag before using. Do not use if it¡¯s damaged